Home > SICK >

SICK: Wire-Draw Encoders (XKS Series)
SICK: Wire-Draw Encoders (XKS Series)


 
Call for Pricing

Price Quote Form


Order #: XKS


Model Number/Code*:


.  
Description Specifications and Drawings
 

XKS

(Wire-Draw Encoders)

Features:

  • Fast and simple integration

  • Compact housing

  • Cost-effective design

  • Integrated measuring system

  • Measuring length up to 5 m

  • High resolution

XKS09-HTBM0227

At a glance:

  • Absolute encoder

  • Compact housing (90 x 90 x 90 mm)

  • Encoder integrated into housing

  • Measuring lengths from 2 to 5 m

  • High resolution

  • Interfaces: HIPERFACE®, PROFIBUS,CANopen and DeviceNET (with adapter)

Benefits:

  • Industrial designed encoder integrated in an aluminum housing makes it less susceptible to external damage, saving time and reducing maintenance costs

  • Extremely precise measurements by eliminating the coupling between the encoder and the mechanism

  • Space-saving installation, since the encoder is directly integrated into the wire draw mechanics.

  • Very precise measurements thanks to the high resolution

  • No reference run necessary thanks to the absolute measuring principle

Performance:

  • Measuring range: 0 m ... 2 m

  • Length of period: 1.195 mm

  • Linearity: ≤ ± 0.7 mm

  • Non-linearity: ± 0.1 mm

  • Piston speed: 3.5 m/s

  • Repeat accuracy typ: ≤0.15 °

Mechanical data:

  • Mass: 1.5 kg

  • Measuring wire diameter: 0.6 mm

  • Measuring wire material: Highly flexible stranded steel (PA 12 sheathed)

  • Housing material: Aluminum

  • Spring return force: 5 N ... 6 N 1)

  • Life of wire draw mechanism:: 800,000 cycles 2) 3)

  • Wire acceleration: ≤ 20 m/s²

1)These values were measred at an ambient temperature of 25 °C. 2)There may be variations at other temperatures.3)At high operating speeds over great lengths,this figure can decrease; at slow oerating speends over short lengths, it can increase.

Electrical data:

  • Operating current: 60 mA (without load)

  • Output frequency for sine/cosine signals: 0 kHz ... 65 kHz

  • Available memory area: 1,792 Byte

  • Supply voltage: 7 V ... 12 V

  • Code type: Binary

  • Code sequence: Rising at wire pull-out

  • MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849) 1)

  • EEprom: 2048 Eeprom

1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

Interfaces:

  • Electrical interface: 7 V ... 12 V, HIPERFACE®

  • Connection type: Male connector M12, 8-pin, radial

  • Interface signals: Parameter channel RS-485: digital, Process data channel SIN, REFSIN,

  • COS, REFCOS: analog, differential

  • Number of sine/cosine periods per revolution: 128

  • Encoder: Absolute encoders

Ambient data:

  • EMC: (according to EN 61000-6-2 and EN 61000-6-3)

  • Enclosure rating encoder: IP 52 (according to IEC 60529), Note required mounting position

  • Resistance to shocks: 20 g, 6 ms (according to EN 60068-2-27)

  • Resistance to vibration: 10 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)

  • Storage temperature range: -20 °C ... +80 °C

  • Relative humidity ∕Condensation: 90 % (Condensation not permitted)

  • Working temperature range (encoder): -10 °C ... +70 °C

XKS09-HTBM0527

At a glance:

  • Absolute encoder

  • Compact housing (90 x 90 x 90 mm)

  • Encoder integrated into housing

  • Measuring lengths from 2 to 5 m

  • High resolution

  • Interfaces: HIPERFACE®, PROFIBUS,CANopen and DeviceNET (with adapter)

Benefits:

  • Industrial designed encoder integrated in an aluminum housing makes it less susceptible to external damage, saving time and reducing maintenance costs

  • Extremely precise measurements by eliminating the coupling between the encoder and the mechanism

  • Space-saving installation, since the encoder is directly integrated into the wire draw mechanics.

  • Very precise measurements thanks to the high resolution

  • No reference run necessary thanks to the absolute measuring principle

Performance:

  • Measuring range: 0 m ... 5 m

  • Length of period: 1.195 mm

  • Linearity: ≤ ± 0.7 mm

  • Non-linearity: ± 0.1 mm

  • Piston speed: 3.5 m/s

  • Repeat accuracy typ: ≤0.15 °

Mechanical data:

  • Mass: 1.5 kg

  • Measuring wire diameter: 0.6 mm

  • Measuring wire material: Highly flexible stranded steel (PA 12 sheathed)

  • Housing material: Aluminum

  • Spring return force: 4 N ... 6 N 1)

  • Life of wire draw mechanism:: 800,000 cycles 2) 3)

  • Wire acceleration: ≤ 20 m/s²

1)These values were measred at an ambient temperature of 25 °C. 2)There may be variations at other temperatures.3)At high operating speeds over great lengths,this figure can decrease; at slow oerating speends over short lengths, it can increase.

Electrical data:

  • Operating current: 60 mA (without load)

  • Output frequency for sine/cosine signals: 0 kHz ... 65 kHz

  • Available memory area: 1,792 Byte

  • Supply voltage: 7 V ... 12 V

  • Code type: Binary

  • Code sequence: Rising at wire pull-out

  • MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849) 1)

  • EEprom: 2048 Eeprom

1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

Interfaces:

  • Electrical interface: 7 V ... 12 V, HIPERFACE®

  • Connection type: Male connector M12, 8-pin, radial

  • Interface signals: Parameter channel RS-485: digital, Process data channel SIN, REFSIN,

  • COS, REFCOS: analog, differential

  • Number of sine/cosine periods per revolution: 128

  • Encoder: Absolute encoders

Ambient data:

  • EMC: (according to EN 61000-6-2 and EN 61000-6-3)

  • Enclosure rating encoder: IP 52 (according to IEC 60529), Note required mounting position

  • Resistance to shocks: 20 g, 6 ms (according to EN 60068-2-27)

  • Resistance to vibration: 10 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)

  • Storage temperature range: -20 °C ... +80 °C

  • Relative humidity ∕Condensation: 90 % (Condensation not permitted)

  • Working temperature range (encoder): -10 °C ... +70 °C


Share your knowledge of this product. Be the first to write a review »